6809665

Brand    DRAGER Product Type    Electrochemical Oxygen SensorDetected Gas    Oxygen (O₂)Measurement Range    0 ~ 25% Vol (Volume Percent)Default Alarm Point    25% VolMinimum/Maximum Adjustment Range    5% / 25% VolDetection Limit    0.2% VolMeasurement Accuracy    ≤ ±1% or ≤ ±0.1% Vol (whichever is greater)Alarm Response Time    ≤ 5 seconds (at 5 times alarm threshold)≤ 15 seconds (at 1.6 times alarm threshold)Warm-up Time    Long Run Preparation Time: 90 minutesLong calibration preparation time: 360 minutesCalibration interval    Default: 9 monthsMinimum/maximum adjustment range: 1 day / 12 monthsAnnual sensitivity decay    ≤ –3%Expected service life    > 36 months (in ambient air)Output signal    AnalogOperating Temperature    -40°C to +65°C (-40°F to 149°F)Operating Humidity    5% to 95% RH (Relative Humidity)Operating Pressure    ±3%Storage Temperature    0°C to 40°C (32°F to 104°F)Key Features    Internal temperature compensation, pressure compensation, pre-calibrated, high stability, long lifespanTranslated with DeepL.com (free version)

Description

Brand    DRAGER

Product Type    Electrochemical Oxygen Sensor

Detected Gas    Oxygen (O₂)

Measurement Range    0 ~ 25% Vol (Volume Percent)

Default Alarm Point    25% Vol

Minimum/Maximum Adjustment Range    5% / 25% Vol

Detection Limit    0.2% Vol

Measurement Accuracy    ≤ ±1% or ≤ ±0.1% Vol (whichever is greater)

Alarm Response Time    ≤ 5 seconds (at 5 times alarm threshold)

≤ 15 seconds (at 1.6 times alarm threshold)

Warm-up Time    Long Run Preparation Time: 90 minutes

Long calibration preparation time: 360 minutes

Calibration interval    Default: 9 months

Minimum/maximum adjustment range: 1 day / 12 months

Annual sensitivity decay    ≤ –3%

Expected service life    > 36 months (in ambient air)

Output signal    Analog

Operating Temperature    -40°C to +65°C (-40°F to 149°F)

Operating Humidity    5% to 95% RH (Relative Humidity)

Operating Pressure    ±3%

Storage Temperature    0°C to 40°C (32°F to 104°F)

Key Features    Internal temperature compensation, pressure compensation, pre-calibrated, high stability, long lifespan